There are multiple types and grades of thermocouple wire. Each type of thermocouple wire has a specific combination of metal alloys. This combination is what defines the type of thermocouple. For example, a type K thermocouple is made when a wire of Nickel-Chromium is welded to a wire of Nickel-Alumel. The grade of the wire is dependent not only on the combination of alloys used, but also on the purity of those alloys. These are used to manufacture the thermocouple probes.
Thermocouple Wire:
1,345 Products FoundView
Buyer
Engineer
Manufacturer
Thermocouple Wire Type
No. of Cores
Length - Imperial
Length - Metric
No. of Max Strands x Strand Size
Wire Gauge
Reel Length (Imperial)
Conductor Area CSA
Reel Length (Metric)
Conductor Type
Colour Code Standard
Insulation
Operating Temperature Min
Operating Temperature Max
Product Range
Packaging
Filter(s) Applied
1 Filter(s) Selected
Compare | Price For | Quantity | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Each | 1+ £175.270 | Min: 1 / Mult: 1 | J | - | 328ft | 100m | 7 x 0.2mm | - | - | 0.219mm² | - | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Each | 1+ £32.690 | Min: 1 / Mult: 1 | J | - | 32.8ft | 10m | 7 x 0.2mm | - | - | 0.219mm² | - | Stranded | IEC | PTFE (Polytetrafluoroethylene) | -75°C | 260°C | - | |||||
Reel of 1 Reel | 1+ £61.290 | Min: 1 / Mult: 1 | E | - | 82ft | 25m | 7 x 0.2mm | - | - | 0.219mm² | - | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Reel of 1 Reel | 1+ £95.350 | Min: 1 / Mult: 1 | J | - | 328ft | 100m | 1 x 0.315mm | - | - | 0.078mm² | - | Stranded | IEC | PTFE (Polytetrafluoroethylene) | -75°C | 260°C | - | |||||
Each | 1+ £305.220 | Min: 1 / Mult: 1 | RTD | - | 164ft | 50m | 7 x 0.2mm | - | - | - | - | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Each | 1+ £204.060 | Min: 1 / Mult: 1 | RTD | 6Core | 82ft | 25m | 7 x 0.2mm | - | - | - | 25m | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Each | 1+ £136.410 | Min: 1 / Mult: 1 | J | - | 328ft | 100m | 1 x 0.2mm | - | - | 0.032mm² | - | Stranded | IEC | PTFE (Polytetrafluoroethylene) | -75°C | 260°C | - | |||||
Each | 1+ £323.800 | Min: 1 / Mult: 1 | K | - | 328ft | 100m | 1 x 0.508mm | - | - | 0.203mm² | - | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Reel of 1 Reel | 1+ £98.700 | Min: 1 / Mult: 1 | E | - | 164ft | 50m | 7 x 0.2mm | - | - | 0.219mm² | - | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Each | 1+ £22.320 10+ £17.750 25+ £15.730 50+ £14.570 100+ £13.730 | Min: 1 / Mult: 1 | K | - | 32.8ft | 10m | 1 x 0.2mm | - | - | 0.032mm² | - | Stranded | IEC | PTFE (Polytetrafluoroethylene) | -75°C | 260°C | - | |||||
Each | 1+ £87.670 5+ £82.130 10+ £77.650 25+ £53.390 50+ £50.520 | Min: 1 / Mult: 1 | K | - | 164ft | 50m | 1 x 0.315mm | - | - | 0.078mm² | - | Stranded | IEC | PTFE (Polytetrafluoroethylene) | -75°C | 260°C | - | |||||
Reel of 1 Reel | 1+ £80.420 5+ £78.520 10+ £76.610 25+ £74.710 50+ £63.660 | Min: 1 / Mult: 1 | K | - | 328ft | 100m | 1 x 0.2mm | - | - | 0.032mm² | - | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Each | 1+ £41.790 5+ £39.140 10+ £37.010 25+ £25.450 50+ £24.080 | Min: 1 / Mult: 1 | K | - | 82ft | 25m | 1 x 0.315mm | - | - | 0.078mm² | - | Stranded | IEC | PTFE (Polytetrafluoroethylene) | -75°C | 260°C | - | |||||
Each | 1+ £238.660 5+ £223.560 10+ £211.380 25+ £145.340 50+ £137.510 | Min: 1 / Mult: 1 | K | - | 328ft | 100m | 1 x 0.315mm | - | - | 0.078mm² | - | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Each | 1+ £44.260 5+ £43.010 10+ £41.750 25+ £40.500 50+ £34.260 | Min: 1 / Mult: 1 | K | - | 164ft | 50m | 1 x 0.2mm | - | - | 0.032mm² | - | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Each | 1+ £27.160 5+ £26.520 10+ £25.870 25+ £25.230 50+ £21.500 | Min: 1 / Mult: 1 | K | - | 32.8ft | 10m | 1 x 0.315mm | - | - | 0.078mm² | - | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Each | 1+ £15.040 10+ £14.260 25+ £13.970 50+ £13.690 100+ £13.400 | Min: 1 / Mult: 1 | K | - | 82ft | 25m | 1 x 0.2mm | - | - | 0.032mm² | - | Stranded | ANSI | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Reel of 1 Reel | 1+ £53.670 5+ £50.990 10+ £48.310 25+ £47.340 50+ £46.380 | Min: 1 / Mult: 1 | T | - | 328ft | 100m | 1 x 0.2mm | - | - | 0.032mm² | - | Stranded | ANSI | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Each | 1+ £46.340 5+ £45.030 10+ £43.710 25+ £42.400 50+ £35.860 | Min: 1 / Mult: 1 | J | - | 164ft | 50m | 1 x 0.2mm | - | - | 0.032mm² | - | Stranded | IEC | PTFE (Polytetrafluoroethylene) | -75°C | 260°C | - | |||||
Each | 1+ £50.430 | Min: 1 / Mult: 1 | K | - | 32.8ft | 10m | 7 x 0.2mm | - | - | 0.219mm² | - | Stranded | IEC | PFA (Perfluoroalkoxy) | -75°C | 260°C | - | |||||
Each | 1+ £669.670 | Min: 1 / Mult: 1 | K | - | 492.13ft | 150m | Solid | 24AWG | - | - | - | Solid | ANSI | PFA | -200°C | 260°C | TT Series | |||||
Each | 1+ £253.530 | Min: 1 / Mult: 1 | N | - | 100ft | 30.48m | Solid | 20AWG | - | - | - | Solid | ANSI | PFA | 0°C | 260°C | TT Series | |||||
Each | 1+ £669.380 | Min: 1 / Mult: 1 | J | - | 1000ft | 304.8m | Solid | 24AWG | - | - | - | Solid | ANSI | TFE (Tetrafluoroethylene) | 0°C | 260°C | TFE Series | |||||
Each | 1+ £781.240 | Min: 1 / Mult: 1 | K | - | 328.08ft | 100m | Solid | 20AWG | - | - | - | Solid | IEC | PFA | -40°C | 260°C | TT Series | |||||
Each | 1+ £438.060 | Min: 1 / Mult: 1 | K | - | 328.08ft | 100m | 7 x 32AWG | 24AWG | - | - | - | Stranded | IEC | PFA | -40°C | 260°C | TT Series |