Power Transducers

: 23 Products Found
Filter Layout:
0 Filter(s) Selected
23 Products Found Please click the 'Apply Filters' button to update results
Min/Max Availability

When the Remember checkbox is selected we will save your latest filter preferences for future searches

Compliance
Min/Max Manufacturer
Min/Max Transducer Function
Min/Max Supply Voltage Min
Min/Max Supply Voltage Max
Min/Max Accuracy %
Min/Max Operating Temperature Min
Min/Max Operating Temperature Max
Min/Max Output Current Max
Min/Max External Depth
Min/Max Input Current
Min/Max Linearity %
Min/Max Product Range

Contract pricing display is unavailable at the moment. Prices shown are standard retail prices, orders placed will have contract pricing applied when processed.

 
Compare Selected Compare
Extended Attributes Attributes
Add properties to the table

Select the properties you would like to see added to the columns at the end of the table.

  Manufacturer Part No Order Code Description / Manufacturer
Availability Price For
Price
Quantity
Transducer Function Supply Voltage Min Supply Voltage Max Accuracy % Operating Temperature Min Operating Temperature Max Output Current Max External Depth Input Current Linearity % Product Range
 
 
Sort Acending Sort Decending Sort Acending Sort Decending Sort Acending Sort Decending Sort Acending Sort Decending Sort Acending Sort Decending Sort Acending Sort Decending Sort Acending Sort Decending Sort Acending Sort Decending Sort Acending Sort Decending Sort Acending Sort Decending Sort Acending Sort Decending
DVL 500
DVL 500 - Voltage Transducer, DVL Series, 500 V, 26.4 Vdc Supply Voltage, 0.5 %

2664170

Voltage Transducer, DVL Series, 500 V, 26.4 Vdc Supply Voltage, 0.5 %

LEM

Transducer Function Voltage Transformer
Supply Voltage Min -13.5V
Supply Voltage Max 26.4V

+ See all product info

LEM 

Voltage Transducer, DVL Series, 500 V, 26.4 Vdc Supply Voltage, 0.5 %

+ Check Stock & Lead Times

20 in stock for next day delivery (Liege stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

7 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 14/09/20

Transducer Function Voltage Transformer
Supply Voltage Min -13.5V
Supply Voltage Max 26.4V
Accuracy % 0.5%
Operating Temperature Min -40°C
Operating Temperature Max 85°C
Output Current Max 75mA
External Depth 100mm
Input Current -
Linearity % 0.5%
Product Range DVL Series

27 In stock

1+ £175.60 Price For 5+ £170.24 Price For 10+ £162.94 Price For

Qty

Each

1+ £175.60 5+ £170.24 10+ £162.94

Restricted Item
Add
Min: 1 Mult: 1
Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 75mA 100mm - 0.5% DVL Series
LV 25-P
LV 25-P - Voltage Transducer, LV Series, 25 mA, -14 mA to 14 mA, 15 Vdc, 0.9 %

1617416

Voltage Transducer, LV Series, 25 mA, -14 mA to 14 mA, 15 Vdc, 0.9 %

LEM

Transducer Function Voltage Transformer
Supply Voltage Min -15V
Supply Voltage Max 15V

+ See all product info

LEM 

Voltage Transducer, LV Series, 25 mA, -14 mA to 14 mA, 15 Vdc, 0.9 %

+ Check Stock & Lead Times

223 in stock for next day delivery (Liege stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

274 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 31/08/20

Transducer Function Voltage Transformer
Supply Voltage Min -15V
Supply Voltage Max 15V
Accuracy % 0.9%
Operating Temperature Min 0°C
Operating Temperature Max 70°C
Output Current Max 25mA
External Depth 29.2mm
Input Current 10mA
Linearity % 0.2%
Product Range -

797 In stock

1+ £52.89 Price For 5+ £51.28 Price For 10+ £49.08 Price For 25+ £48.10 Price For

Qty

Each

1+ £52.89 5+ £51.28 10+ £49.08 25+ £48.10

Restricted Item
Add
Min: 1 Mult: 1
Voltage Transformer -15V 15V 0.9% 0°C 70°C 25mA 29.2mm 10mA 0.2% -
MACX MCR-VDC
MACX MCR-VDC - Voltage Transducer, MACX Series, -660 to 660 Vdc, 24 Vdc, 1 %, -10 to 10 V Output

2523211

Voltage Transducer, MACX Series, -660 to 660 Vdc, 24 Vdc, 1 %, -10 to 10 V Output

PHOENIX CONTACT

Transducer Function DC Voltage Input
Supply Voltage Min 19.2V
Supply Voltage Max 30V

+ See all product info

PHOENIX CONTACT 

Voltage Transducer, MACX Series, -660 to 660 Vdc, 24 Vdc, 1 %, -10 to 10 V Output

+ Check Stock & Lead Times

6 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 17/08/20

Transducer Function DC Voltage Input
Supply Voltage Min 19.2V
Supply Voltage Max 30V
Accuracy % -
Operating Temperature Min -25°C
Operating Temperature Max 60°C
Output Current Max 22mA
External Depth 114.5mm
Input Current -
Linearity % -
Product Range -

6 In stock

1+ £247.16 Price For 5+ £242.22 Price For

Qty

Each

1+ £247.16 5+ £242.22

Restricted Item
Add
Min: 1 Mult: 1
DC Voltage Input 19.2V 30V - -25°C 60°C 22mA 114.5mm - - -
DVL 750
DVL 750 - Voltage Transducer, DVL Series, 750 V, 26.4 Vdc Supply Voltage, 0.5 %

2664173

Voltage Transducer, DVL Series, 750 V, 26.4 Vdc Supply Voltage, 0.5 %

LEM

Transducer Function Voltage Transformer
Supply Voltage Min -13.5V
Supply Voltage Max 26.4V

+ See all product info

LEM 

Voltage Transducer, DVL Series, 750 V, 26.4 Vdc Supply Voltage, 0.5 %

+ Check Stock & Lead Times

1 in stock for next day delivery (Liege stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

2 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

  • 12 more will be available on 12/08/20
  • More stock available week commencing 14/09/20

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 75mA
    External Depth 100mm
    Input Current -
    Linearity % 0.5%
    Product Range DVL Series

    3 In stock

    1+ £193.22 Price For 5+ £187.31 Price For 10+ £179.28 Price For

    Qty

    Each

    1+ £193.22 5+ £187.31 10+ £179.28

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 75mA 100mm - 0.5% DVL Series
    DVL 2000
    DVL 2000 - Voltage Transducer, DVL Series, 2 kV, 26.4 Vdc Supply Voltage, 0.5 %

    2664166

    Voltage Transducer, DVL Series, 2 kV, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, DVL Series, 2 kV, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    7 in stock for next day delivery (Liege stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    More stock available week commencing 14/09/20

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 75mA
    External Depth 100mm
    Input Current -
    Linearity % 0.5%
    Product Range DVL Series

    7 In stock

    1+ £175.60 Price For 5+ £170.24 Price For 10+ £162.94 Price For

    Qty

    Each

    1+ £175.60 5+ £170.24 10+ £162.94

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 75mA 100mm - 0.5% DVL Series
    DVL 1000
    DVL 1000 - Voltage Transducer, DVL Series, 1 kV, 26.4 Vdc Supply Voltage, 0.5 %

    2664159

    Voltage Transducer, DVL Series, 1 kV, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, DVL Series, 1 kV, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    5 in stock for next day delivery (Liege stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    18 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    More stock available week commencing 14/09/20

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 75mA
    External Depth 100mm
    Input Current 20mA
    Linearity % 0.5%
    Product Range DVL Series

    36 In stock

    1+ £171.11 Price For 5+ £165.88 Price For 10+ £158.78 Price For

    Qty

    Each

    1+ £171.11 5+ £165.88 10+ £158.78

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 75mA 100mm 20mA 0.5% DVL Series
    DVL 750-UI
    DVL 750-UI - Voltage Transducer, Unipolar, DVL-UI Series, 750 V, 26.4 Vdc Supply Voltage, 0.5 %

    2664174

    Voltage Transducer, Unipolar, DVL-UI Series, 750 V, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, Unipolar, DVL-UI Series, 750 V, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    9 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    More stock available week commencing 12/10/20

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 21mA
    External Depth 100mm
    Input Current 25mA
    Linearity % 0.5%
    Product Range DVL-UI Series

    9 In stock

    1+ £211.31 Price For 5+ £204.86 Price For

    Qty

    Each

    1+ £211.31 5+ £204.86

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 21mA 100mm 25mA 0.5% DVL-UI Series
    2906244
    2906244 - Voltage Transducer, AC Voltage Input, MACX MCR, 30 Vdc, 0.045 A

    2885919

    Voltage Transducer, AC Voltage Input, MACX MCR, 30 Vdc, 0.045 A

    PHOENIX CONTACT

    Transducer Function AC Voltage Input
    Supply Voltage Min 19.2VDC
    Supply Voltage Max 30VDC

    + See all product info

    PHOENIX CONTACT 

    Voltage Transducer, AC Voltage Input, MACX MCR, 30 Vdc, 0.045 A

    + Check Stock & Lead Times

    1 in stock for next day delivery (Liege stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    More stock available week commencing 17/08/20

    Transducer Function AC Voltage Input
    Supply Voltage Min 19.2VDC
    Supply Voltage Max 30VDC
    Accuracy % -
    Operating Temperature Min -25°C
    Operating Temperature Max 60°C
    Output Current Max 22mA
    External Depth 114.5mm
    Input Current 45mA
    Linearity % -
    Product Range -

    1 In stock

    1+ £284.32 Price For 5+ £278.63 Price For

    Qty

    Each

    1+ £284.32 5+ £278.63

    Restricted Item
    Add
    Min: 1 Mult: 1
    AC Voltage Input 19.2VDC 30VDC - -25°C 60°C 22mA 114.5mm 45mA - -
    DVL 1500-UI
    DVL 1500-UI - Voltage Transducer, Unipolar, DVL-UI Series, 1.5 kV, 26.4 Vdc Supply Voltage, 0.5 %

    2664164

    Voltage Transducer, Unipolar, DVL-UI Series, 1.5 kV, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, Unipolar, DVL-UI Series, 1.5 kV, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    21 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    More stock available week commencing 12/10/20

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 21mA
    External Depth 100mm
    Input Current 25mA
    Linearity % 0.5%
    Product Range DVL-UI Series

    21 In stock

    1+ £211.31 Price For 5+ £204.86 Price For

    Qty

    Each

    1+ £211.31 5+ £204.86

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 21mA 100mm 25mA 0.5% DVL-UI Series
    DVL 125
    DVL 125 - Voltage Transducer, DVL Series, 125 V, 26.4 Vdc Supply Voltage, 0.5 %

    2664161

    Voltage Transducer, DVL Series, 125 V, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, DVL Series, 125 V, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    1 in stock for next day delivery (Liege stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    1 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    More stock available week commencing 14/09/20

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 75.2mA
    External Depth 100mm
    Input Current -
    Linearity % 0.5%
    Product Range DVL Series

    2 In stock

    1+ £180.00 Price For 5+ £174.00 Price For 10+ £168.00 Price For

    Qty

    Each

    1+ £180.00 5+ £174.00 10+ £168.00

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 75.2mA 100mm - 0.5% DVL Series
    DVL 1500
    DVL 1500 - Voltage Transducer, DVL Series, 1.5 kV, 26.4 Vdc Supply Voltage, 0.5 %

    2664163

    Voltage Transducer, DVL Series, 1.5 kV, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, DVL Series, 1.5 kV, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    25 in stock for next day delivery (Liege stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    2 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    More stock available week commencing 12/10/20

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 75mA
    External Depth 100mm
    Input Current -
    Linearity % 0.5%
    Product Range DVL Series

    27 In stock

    1+ £171.11 Price For 5+ £165.88 Price For 10+ £158.77 Price For

    Qty

    Each

    1+ £171.11 5+ £165.88 10+ £158.77

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 75mA 100mm - 0.5% DVL Series
    DVL 150
    DVL 150 - Voltage Transducer, DVL Series, 150 V, 26.4 Vdc Supply Voltage, 0.5 %

    2664162

    Voltage Transducer, DVL Series, 150 V, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, DVL Series, 150 V, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    3 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    More stock available week commencing 14/09/20

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 75mA
    External Depth 100mm
    Input Current -
    Linearity % 0.5%
    Product Range DVL Series

    3 In stock

    1+ £174.00 Price For 5+ £171.00 Price For 10+ £167.00 Price For

    Qty

    Each

    1+ £174.00 5+ £171.00 10+ £167.00

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 75mA 100mm - 0.5% DVL Series
    DVL 250-UI
    DVL 250-UI - Voltage Transducer, Unipolar, DVL-UI Series, 250 V, 26.4 Vdc Supply Voltage, 0.5 %

    2664168

    Voltage Transducer, Unipolar, DVL-UI Series, 250 V, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, Unipolar, DVL-UI Series, 250 V, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    1 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    More stock available week commencing 12/10/20

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 21mA
    External Depth 100mm
    Input Current 25mA
    Linearity % 0.5%
    Product Range DVL-UI Series

    1 In stock

    1+ £211.31 Price For 5+ £204.86 Price For

    Qty

    Each

    1+ £211.31 5+ £204.86

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 21mA 100mm 25mA 0.5% DVL-UI Series
    2906239
    2906239 - Voltage Transducer, AC Voltage Input, MACX MCR, 30 Vdc, 0.045 A

    2885917

    Voltage Transducer, AC Voltage Input, MACX MCR, 30 Vdc, 0.045 A

    PHOENIX CONTACT

    Transducer Function AC Voltage Input
    Supply Voltage Min 19.2VDC
    Supply Voltage Max 30VDC

    + See all product info

    PHOENIX CONTACT 

    Voltage Transducer, AC Voltage Input, MACX MCR, 30 Vdc, 0.045 A

    + Check Stock & Lead Times

    2 in stock for next day delivery (Liege stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    6 in stock for next day delivery (UK stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    More stock available week commencing 17/08/20

    Transducer Function AC Voltage Input
    Supply Voltage Min 19.2VDC
    Supply Voltage Max 30VDC
    Accuracy % -
    Operating Temperature Min -25°C
    Operating Temperature Max 60°C
    Output Current Max 22mA
    External Depth 114.5mm
    Input Current 45mA
    Linearity % -
    Product Range -

    8 In stock

    1+ £284.32 Price For 5+ £278.63 Price For

    Qty

    Each

    1+ £284.32 5+ £278.63

    Restricted Item
    Add
    Min: 1 Mult: 1
    AC Voltage Input 19.2VDC 30VDC - -25°C 60°C 22mA 114.5mm 45mA - -
    DVL 500-UI
    DVL 500-UI - Voltage Transducer, Unipolar, DVL-UI Series, 500 V, 26.4 Vdc Supply Voltage, 0.5 %

    2664171

    Voltage Transducer, Unipolar, DVL-UI Series, 500 V, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, Unipolar, DVL-UI Series, 500 V, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    2 in stock for next day delivery (Liege stock): Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

    Available until stock is exhausted
    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 21mA
    External Depth 100mm
    Input Current 25mA
    Linearity % 0.5%
    Product Range DVL-UI Series

    2 In stock

    1+ £106.00 Price For

    Qty

    Each

    Available until stock is exhausted

    1+ £106.00

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 21mA 100mm 25mA 0.5% DVL-UI Series
    DVL 1000-UI
    DVL 1000-UI - Voltage Transducer, Unipolar, DVL-UI Series, 1 kV, 26.4 Vdc Supply Voltage, 0.5 %

    2664160

    Voltage Transducer, Unipolar, DVL-UI Series, 1 kV, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, Unipolar, DVL-UI Series, 1 kV, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times
  • 6 more will be available on 09/08/20
  • 6 more will be available on 16/08/20
  • 12 more will be available on 23/08/20
  • More stock available week commencing 12/10/20 Contact me when back in stock
    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 21mA
    External Depth 100mm
    Input Current 25mA
    Linearity % 0.5%
    Product Range DVL-UI Series

    N/A

    1+ £210.70 Price For 5+ £204.27 Price For

    Qty

    Each

    1+ £210.70 5+ £204.27

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 21mA 100mm 25mA 0.5% DVL-UI Series
    DVC 1000-P
    DVC 1000-P - VOLTAGE TRANSDUCER, 1000V

    3253138

     
    New product
    Data Sheet
    +
    RoHS

    VOLTAGE TRANSDUCER, 1000V

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min 4.75V
    Supply Voltage Max 5.25V

    + See all product info

    LEM 

    VOLTAGE TRANSDUCER, 1000V New

    + Check Stock & Lead Times
  • 5 more will be available on 18/07/20
  • More stock available week commencing 23/11/20 Contact me when back in stock
    Transducer Function Voltage Transformer
    Supply Voltage Min 4.75V
    Supply Voltage Max 5.25V
    Accuracy % 1%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 35mA
    External Depth 43mm
    Input Current -
    Linearity % 0.2%
    Product Range DVC Series

    N/A

    1+ £58.12 Price For 5+ £56.96 Price For 10+ £55.80 Price For 25+ £54.63 Price For

    Qty

    Each

    1+ £58.12 5+ £56.96 10+ £55.80 25+ £54.63

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer 4.75V 5.25V 1% -40°C 85°C 35mA 43mm - 0.2% DVC Series
    DVL 50
    DVL 50 - Voltage Transducer, DVL Series, 50 V, 26.4 Vdc Supply Voltage, 0.5 %

    2664169

    Voltage Transducer, DVL Series, 50 V, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, DVL Series, 50 V, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times
  • 21 more will be available on 26/07/20
  • More stock available week commencing 14/09/20 Contact me when back in stock
    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 75mA
    External Depth 100mm
    Input Current -
    Linearity % 0.5%
    Product Range DVL Series

    N/A

    1+ £171.11 Price For 5+ £165.89 Price For 10+ £158.77 Price For

    Qty

    Each

    1+ £171.11 5+ £165.89 10+ £158.77

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 75mA 100mm - 0.5% DVL Series
    2906243
    2906243 - Voltage Transducer, DC Voltage Input, MACX MCR, 30 Vdc, 0.06 A

    2885918

    Voltage Transducer, DC Voltage Input, MACX MCR, 30 Vdc, 0.06 A

    PHOENIX CONTACT

    Transducer Function DC Voltage Input
    Supply Voltage Min 19.2VDC
    Supply Voltage Max 30VDC

    + See all product info

    PHOENIX CONTACT 

    Voltage Transducer, DC Voltage Input, MACX MCR, 30 Vdc, 0.06 A

    + Check Stock & Lead Times

    More stock available week commencing 17/08/20 Contact me when back in stock
    Transducer Function DC Voltage Input
    Supply Voltage Min 19.2VDC
    Supply Voltage Max 30VDC
    Accuracy % -
    Operating Temperature Min -25°C
    Operating Temperature Max 60°C
    Output Current Max 22mA
    External Depth 114.5mm
    Input Current 60mA
    Linearity % -
    Product Range -

    N/A

    1+ £247.16 Price For 5+ £242.22 Price For

    Qty

    Each

    1+ £247.16 5+ £242.22

    Restricted Item
    Add
    Min: 1 Mult: 1
    DC Voltage Input 19.2VDC 30VDC - -25°C 60°C 22mA 114.5mm 60mA - -
    DVL 150-UI
    DVL 150-UI - Voltage Transducer, Unipolar, DVL-UI Series, 150 V, 26.4 Vdc Supply Voltage, 0.5 %

    2664165

    Voltage Transducer, Unipolar, DVL-UI Series, 150 V, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, Unipolar, DVL-UI Series, 150 V, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    More stock available week commencing 12/10/20 Contact me when back in stock
    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 21mA
    External Depth 100mm
    Input Current 25mA
    Linearity % 0.5%
    Product Range DVL-UI Series

    N/A

    1+ £210.70 Price For 5+ £204.27 Price For

    Qty

    Each

    1+ £210.70 5+ £204.27

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 21mA 100mm 25mA 0.5% DVL-UI Series
    DVL 50-UI
    DVL 50-UI - Voltage Transducer, Unipolar, DVL-UI Series, 50 V, 26.4 Vdc Supply Voltage, 0.5 %

    2664172

    Voltage Transducer, Unipolar, DVL-UI Series, 50 V, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, Unipolar, DVL-UI Series, 50 V, 26.4 Vdc Supply Voltage, 0.5 %

    + Check Stock & Lead Times

    More stock available week commencing 12/10/20 Contact me when back in stock
    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 21mA
    External Depth 100mm
    Input Current 25mA
    Linearity % 0.5%
    Product Range DVL-UI Series

    N/A

    1+ £210.70 Price For 5+ £204.27 Price For

    Qty

    Each

    1+ £210.70 5+ £204.27

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 21mA 100mm 25mA 0.5% DVL-UI Series
    DVL 250
    DVL 250 - Voltage Transducer, DVL Series, 250 V, 26.4 Vdc Supply Voltage, 0.5 %

    2664167

    Voltage Transducer, DVL Series, 250 V, 26.4 Vdc Supply Voltage, 0.5 %

    LEM

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V

    + See all product info

    LEM 

    Voltage Transducer, DVL Series, 250 V, 26.4 Vdc Supply Voltage, 0.5 %

    Transducer Function Voltage Transformer
    Supply Voltage Min -13.5V
    Supply Voltage Max 26.4V
    Accuracy % 0.5%
    Operating Temperature Min -40°C
    Operating Temperature Max 85°C
    Output Current Max 75mA
    External Depth 100mm
    Input Current -
    Linearity % 0.5%
    Product Range DVL Series

    N/A

    Qty

    Each

    Restricted Item
    Add
    Min: 1 Mult: 1
    Voltage Transformer -13.5V 26.4V 0.5% -40°C 85°C 75mA 100mm - 0.5% DVL Series
    MCR-VDC-UI-B-DC
    MCR-VDC-UI-B-DC - INTERFACE ANALOG

    1706203

    INTERFACE ANALOG

    PHOENIX CONTACT

    Supply Voltage Min 18.5VDC
    Supply Voltage Max 30.2VDC
    Accuracy % 1%

    + See all product info

    PHOENIX CONTACT 

    INTERFACE ANALOG

    Transducer Function -
    Supply Voltage Min 18.5VDC
    Supply Voltage Max 30.2VDC
    Accuracy % 1%
    Operating Temperature Min -25°C
    Operating Temperature Max 50°C
    Output Current Max 20mA
    External Depth 114.5mm
    Input Current -
    Linearity % -
    Product Range -

    N/A

    Qty

    Each

    Restricted Item
    Add
    Min: 1 Mult: 1
    - 18.5VDC 30.2VDC 1% -25°C 50°C 20mA 114.5mm - - -