Bourns Logo

Bourns SA2 Series Gas Discharge Tubes

High Voltage Gas Discharge Tubes designed for high isolation applications including welders, street lighting and power supplies.

  • Fast switching rate
  • High energy, low loss capability
  • Wide operating temperature range
  • Long service life
  • High insulation resistance
SA2 Series Gas Discharge Tubes

Product Description

The SA2 Series two-electrode High Voltage Gas Discharge Tube from Bourns are reliable, responsive and designed for a long life of hard work. With a high insulation resistance over an incredibly wide temperature range of 40 °C to +125 °C the SA2 Series GDTs are ideal for hard wearing applications where reliability is paramount. These GDTs are most commonly seen in applications such as street lighting, power supplies, projectors, welders and medical devices.

The SA2 GDTs are available in a DC breakdown range between 2.4 kV to 7.2 kV, come with Matte Tin plating and are RoHS compliant.

Customized Voltages Available

Other customized voltages between 2 kV and 7.2 kV are available upon request.

Reliable & Long Lasting

Intended for use in street lighting, power supplies, projectors, welders and medical devices the SA2 Series are designed for a long service life the highest standards of reliability.

High Insulation Resistance

SA2 series GDTs can boast a high insulation resistance over an incredibly wide temperature range of 40 °C to +125 °C.

Product Series
Compare Selected Compare Add Selected Add

Contract pricing display is unavailable at the moment. Prices shown are standard retail prices, orders placed will have contract pricing applied when processed.

  Manufacturer Part No Order Code Manufacturer / Description
Avail Price For
Price
Quantity
SA2-7200-CLT-STD
SA2-7200-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 8.64 kV, Axial Leaded, 5 kA, 10 kV

2300297

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 8.64 kV, Axial Leaded, 5 kA, 10 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 7.2KV; Product Range:SA2 Series; DC Breakover Voltage:8.64kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:10kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

4,420 in stock

+ Check Stock & Lead Times

280 Liege Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

4,140 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 11/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300297
2300297RL in Re-reel

1+ £2.80 50+ £1.93 100+ £1.58 250+ £1.53 500+ £1.31 1000+ £1.11 5000+ £1.09 10000+ £1.07 More Pricing...

Add
Min: 1 Mult: 1
SA2-4500-CLT-STD
SA2-4500-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series

2300293

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series

GAS DISCHARGE TUBE, HIGH V, 2POL, 4.5KV; Product Range:SA2 Series; DC Breakover Voltage:-; GDT Case Style:-; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

442 in stock

+ Check Stock & Lead Times

442 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 11/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300293
2300293RL in Re-reel

1+ £1.02 50+ £0.981 100+ £0.972 250+ £0.963 500+ £0.954 1000+ £0.951 5000+ £0.95 10000+ £0.949 More Pricing...

Add
Min: 1 Mult: 1
ST-0620-BLT-STD
ST-0620-BLT-STD - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0620 Series, 620 V, Axial Leaded

2300300

BOURNS - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0620 Series, 620 V, Axial Leaded

GAS DISCHARGE TUBE, 750A, 2POL, 620V; Product Range:Sparctube ST-0620 Series; DC Breakover Voltage:620V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

409 in stock

+ Check Stock & Lead Times

409 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 04/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300300
2300300RL in Re-reel

1+ £1.21 50+ £1.14 100+ £1.10 250+ £1.04 500+ £0.999 1000+ £0.806 5000+ £0.79 10000+ £0.774 More Pricing...

Add
Min: 1 Mult: 1
ST-0470-BLT-STD
ST-0470-BLT-STD - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0470 Series, 470 V, Axial Leaded

2300302

BOURNS - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0470 Series, 470 V, Axial Leaded

GAS DISCHARGE TUBE, 500A, 2POL, 470V; Product Range:Sparctube ST-0470 Series; DC Breakover Voltage:470V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

335 in stock

+ Check Stock & Lead Times

335 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 04/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300302
2300302RL in Re-reel

1+ £1.73 50+ £1.38 100+ £1.16 250+ £1.13 500+ £0.963 1000+ £0.806 5000+ £0.79 10000+ £0.774 More Pricing...

Add
Min: 1 Mult: 1
SA2-6200-CLT-STD
SA2-6200-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 7.44 kV, Axial Leaded, 5 kA, 8 kV

2300295

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 7.44 kV, Axial Leaded, 5 kA, 8 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 6.2KV; Product Range:SA2 Series; DC Breakover Voltage:7.44kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:8kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

196 in stock

+ Check Stock & Lead Times

11 Liege Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

185 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 11/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300295
2300295RL in Re-reel

1+ £1.39 50+ £1.25 100+ £1.21 250+ £1.16 500+ £1.11 1000+ £1.04 5000+ £1.02 10000+ £0.998 More Pricing...

Add
Min: 1 Mult: 1
ST-0840-BLT-STD
ST-0840-BLT-STD - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0840 Series, 840 V, Axial Leaded

2300298

BOURNS - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0840 Series, 840 V, Axial Leaded

GAS DISCHARGE TUBE, 450A, 2POL, 840V; Product Range:Sparctube ST-0840 Series; DC Breakover Voltage:840V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

99 in stock

+ Check Stock & Lead Times

2 Liege Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

97 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 04/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300298
2300298RL in Re-reel

1+ £1.98 50+ £1.61 100+ £1.36 250+ £1.33 500+ £1.13 1000+ £1.09 5000+ £1.04 10000+ £1.00 More Pricing...

Add
Min: 1 Mult: 1
ST-0600-BLT-STD
ST-0600-BLT-STD - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0600 Series, 600 V, Axial Leaded

2300301

BOURNS - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0600 Series, 600 V, Axial Leaded

GAS DISCHARGE TUBE, 750A, 2POL, 600V; Product Range:Sparctube ST-0600 Series; DC Breakover Voltage:600V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

98 in stock

+ Check Stock & Lead Times

98 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 04/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300301
2300301RL in Re-reel

1+ £1.69 50+ £1.46 100+ £1.23 250+ £1.20 500+ £1.01 1000+ £0.806 5000+ £0.79 10000+ £0.774 More Pricing...

Add
Min: 1 Mult: 1
SA2-3000-CLT-STD
SA2-3000-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, 3.6 kV, Axial Leaded, 5 kA, 4.5 kV

2300290

BOURNS - Gas Discharge Tube (GDT), High-Voltage, 3.6 kV, Axial Leaded, 5 kA, 4.5 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 3KV; Product Range:-; DC Breakover Voltage:3.6kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:4.5kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

Cut Tape
Packaging Options
Suggested replacement for:2300290
2300290RL in Re-reel
SA2-3600-CLT-STD
SA2-3600-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 4.32 kV, Axial Leaded, 5 kA, 5.4 kV

2300292

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 4.32 kV, Axial Leaded, 5 kA, 5.4 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 3.6KV; Product Range:SA2 Series; DC Breakover Voltage:4.32kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:5.4kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

Cut Tape
Packaging Options
Suggested replacement for:2300292
2300292RL in Re-reel
SA2-5500-CLT-STD
SA2-5500-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 6.6 kV, Axial Leaded, 5 kA, 8 kV

2300294

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 6.6 kV, Axial Leaded, 5 kA, 8 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 5.5KV; Product Range:SA2 Series; DC Breakover Voltage:6.6kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:8kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

Cut Tape
Packaging Options
Suggested replacement for:2300294
2300294RL in Re-reel
SA2-6300-CLT-STD
SA2-6300-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 7.56 kV, Axial Leaded, 5 kA, 9.2 kV

2300296

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 7.56 kV, Axial Leaded, 5 kA, 9.2 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 6.3KV; Product Range:SA2 Series; DC Breakover Voltage:7.56kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:9.2kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

Cut Tape
Packaging Options
Suggested replacement for:2300296
2300296RL in Re-reel
ST-0400-BLT-STD
ST-0400-BLT-STD - Gas Discharge Tube (GDT), 400 V, Axial Leaded

2300303

BOURNS - Gas Discharge Tube (GDT), 400 V, Axial Leaded

GAS DISCHARGE TUBE, 500A, 2POL, 400V; Product Range:-; DC Breakover Voltage:400V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

ST-0800-BLT-STD
ST-0800-BLT-STD - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0800 Series, 800 V, Axial Leaded

2300299

BOURNS - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0800 Series, 800 V, Axial Leaded

GAS DISCHARGE TUBE, 450A, 2POL, 800V; Product Range:Sparctube ST-0800 Series; DC Breakover Voltage:800V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

Cut Tape
Packaging Options
Suggested replacement for:2300299
2300299RL in Re-reel

Related products
Compare Selected Compare Add Selected Add

Contract pricing display is unavailable at the moment. Prices shown are standard retail prices, orders placed will have contract pricing applied when processed.

  Manufacturer Part No Order Code Manufacturer / Description
Avail Price For
Price
Quantity
SA2-7200-CLT-STD
SA2-7200-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 8.64 kV, Axial Leaded, 5 kA, 10 kV

2300297

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 8.64 kV, Axial Leaded, 5 kA, 10 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 7.2KV; Product Range:SA2 Series; DC Breakover Voltage:8.64kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:10kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

4,420 in stock

+ Check Stock & Lead Times

280 Liege Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

4,140 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 11/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300297
2300297RL in Re-reel

1+ £2.80 50+ £1.93 100+ £1.58 250+ £1.53 500+ £1.31 1000+ £1.11 5000+ £1.09 10000+ £1.07 More Pricing...

Add
Min: 1 Mult: 1
SA2-4500-CLT-STD
SA2-4500-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series

2300293

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series

GAS DISCHARGE TUBE, HIGH V, 2POL, 4.5KV; Product Range:SA2 Series; DC Breakover Voltage:-; GDT Case Style:-; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

442 in stock

+ Check Stock & Lead Times

442 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 11/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300293
2300293RL in Re-reel

1+ £1.02 50+ £0.981 100+ £0.972 250+ £0.963 500+ £0.954 1000+ £0.951 5000+ £0.95 10000+ £0.949 More Pricing...

Add
Min: 1 Mult: 1
ST-0620-BLT-STD
ST-0620-BLT-STD - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0620 Series, 620 V, Axial Leaded

2300300

BOURNS - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0620 Series, 620 V, Axial Leaded

GAS DISCHARGE TUBE, 750A, 2POL, 620V; Product Range:Sparctube ST-0620 Series; DC Breakover Voltage:620V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

409 in stock

+ Check Stock & Lead Times

409 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 04/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300300
2300300RL in Re-reel

1+ £1.21 50+ £1.14 100+ £1.10 250+ £1.04 500+ £0.999 1000+ £0.806 5000+ £0.79 10000+ £0.774 More Pricing...

Add
Min: 1 Mult: 1
ST-0470-BLT-STD
ST-0470-BLT-STD - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0470 Series, 470 V, Axial Leaded

2300302

BOURNS - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0470 Series, 470 V, Axial Leaded

GAS DISCHARGE TUBE, 500A, 2POL, 470V; Product Range:Sparctube ST-0470 Series; DC Breakover Voltage:470V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

335 in stock

+ Check Stock & Lead Times

335 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 04/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300302
2300302RL in Re-reel

1+ £1.73 50+ £1.38 100+ £1.16 250+ £1.13 500+ £0.963 1000+ £0.806 5000+ £0.79 10000+ £0.774 More Pricing...

Add
Min: 1 Mult: 1
SA2-6200-CLT-STD
SA2-6200-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 7.44 kV, Axial Leaded, 5 kA, 8 kV

2300295

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 7.44 kV, Axial Leaded, 5 kA, 8 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 6.2KV; Product Range:SA2 Series; DC Breakover Voltage:7.44kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:8kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

196 in stock

+ Check Stock & Lead Times

11 Liege Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

185 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 11/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300295
2300295RL in Re-reel

1+ £1.39 50+ £1.25 100+ £1.21 250+ £1.16 500+ £1.11 1000+ £1.04 5000+ £1.02 10000+ £0.998 More Pricing...

Add
Min: 1 Mult: 1
ST-0840-BLT-STD
ST-0840-BLT-STD - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0840 Series, 840 V, Axial Leaded

2300298

BOURNS - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0840 Series, 840 V, Axial Leaded

GAS DISCHARGE TUBE, 450A, 2POL, 840V; Product Range:Sparctube ST-0840 Series; DC Breakover Voltage:840V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

99 in stock

+ Check Stock & Lead Times

2 Liege Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

97 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 04/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300298
2300298RL in Re-reel

1+ £1.98 50+ £1.61 100+ £1.36 250+ £1.33 500+ £1.13 1000+ £1.09 5000+ £1.04 10000+ £1.00 More Pricing...

Add
Min: 1 Mult: 1
ST-0600-BLT-STD
ST-0600-BLT-STD - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0600 Series, 600 V, Axial Leaded

2300301

BOURNS - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0600 Series, 600 V, Axial Leaded

GAS DISCHARGE TUBE, 750A, 2POL, 600V; Product Range:Sparctube ST-0600 Series; DC Breakover Voltage:600V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

98 in stock

+ Check Stock & Lead Times

98 UK Stock: Order before 20:00(mainland UK) & 18.00(NI) (for re-reeled items 16:30 – mainland UK & NI) Mon-Fri (excluding National Holidays)

More stock available week commencing 04/12/17

Each (Supplied on Cut Tape)

Cut Tape
Packaging Options
Suggested replacement for:2300301
2300301RL in Re-reel

1+ £1.69 50+ £1.46 100+ £1.23 250+ £1.20 500+ £1.01 1000+ £0.806 5000+ £0.79 10000+ £0.774 More Pricing...

Add
Min: 1 Mult: 1
SA2-3600-CLT-STD
SA2-3600-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 4.32 kV, Axial Leaded, 5 kA, 5.4 kV

2300292

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 4.32 kV, Axial Leaded, 5 kA, 5.4 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 3.6KV; Product Range:SA2 Series; DC Breakover Voltage:4.32kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:5.4kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

Cut Tape
Packaging Options
Suggested replacement for:2300292
2300292RL in Re-reel
SA2-5500-CLT-STD
SA2-5500-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 6.6 kV, Axial Leaded, 5 kA, 8 kV

2300294

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 6.6 kV, Axial Leaded, 5 kA, 8 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 5.5KV; Product Range:SA2 Series; DC Breakover Voltage:6.6kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:8kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

Cut Tape
Packaging Options
Suggested replacement for:2300294
2300294RL in Re-reel
SA2-6300-CLT-STD
SA2-6300-CLT-STD - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 7.56 kV, Axial Leaded, 5 kA, 9.2 kV

2300296

BOURNS - Gas Discharge Tube (GDT), High-Voltage, SA2 Series, 7.56 kV, Axial Leaded, 5 kA, 9.2 kV

GAS DISCHARGE TUBE, HIGH V, 2POL, 6.3KV; Product Range:SA2 Series; DC Breakover Voltage:7.56kV; GDT Case Style:Axial Leaded; Impulse Discharge Current:5kA; Impulse Sparkover Voltage:9.2kV; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

Cut Tape
Packaging Options
Suggested replacement for:2300296
2300296RL in Re-reel
ST-0400-BLT-STD
ST-0400-BLT-STD - Gas Discharge Tube (GDT), 400 V, Axial Leaded

2300303

BOURNS - Gas Discharge Tube (GDT), 400 V, Axial Leaded

GAS DISCHARGE TUBE, 500A, 2POL, 400V; Product Range:-; DC Breakover Voltage:400V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

ST-0800-BLT-STD
ST-0800-BLT-STD - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0800 Series, 800 V, Axial Leaded

2300299

BOURNS - Gas Discharge Tube (GDT), Switching Spark, Sparctube ST-0800 Series, 800 V, Axial Leaded

GAS DISCHARGE TUBE, 450A, 2POL, 800V; Product Range:Sparctube ST-0800 Series; DC Breakover Voltage:800V; GDT Case Style:Axial Leaded; Impulse Discharge Current:-; Impulse Sparkover Voltage:-; SVHC:No SVHC (20-Jun-2016); Packaging:Cut Tape

No Longer Stocked

Cut Tape
Packaging Options
Suggested replacement for:2300299
2300299RL in Re-reel